Vidispine
Aspera Integration [VC 21.3.1 GEN]
Vidispine can initiate transfers between storages using Aspera. For this to work, the source and destination storages must first be configured properly.
Source storage configuration
The following metadata fields must be set on the storage (Key-value metadata).
asperaRootPath
The absolute path to the storage root
Example: /usr/local/aspera-storage/
asperaWsdlLocation
The URL to the FIMS WSDL file for the Transfer Service
Example: http://10.18.12.10:8080/FIMS/TransferService?wsdl>
asperaStatusWsdlLocation
The URL to the FIMS WSDL for the Transfer Status Service.
Example: http://10.18.12.10:8080/FIMS/TransferStatusService?wsdl>
If performing a transfer from this storage, and the destination is an Aspera URL, then Aspera will be used for the transfer.
Destination storage configuration
asperaDestinationUri
The Aspera URI corresponding to the root folder of this storage
Example: fasp://10.18.12.11:22/usr/local/aspera-destination?user=username&password=password&targetrate=1000&minrate=1000&v=2
If a transfer is initiated to this storage, and the source storage is also configured for Aspera transfer, then Aspera will be used for the transfer.